Best-value Lus package for non-contact laser-ultrasonic detection on close range or reflective surfaces.
We’ve got you covered, from advanced discovering non-contact testing to full laser-ultrasonic exploration and ultimate integration.
Talk to an expertBest-value Lus package for non-contact laser-ultrasonic detection on close range or reflective surfaces.
A complete laser-ultrasonic system tailored for laboratory studies.
Upgrade your system with an ultra-high-power detection laser and a long-range high-efficiency probe.
The turnkey laser-ultrasonic station that will accelerate your application development.
The affordable, plug-and-play non-contact ultrasonic detection unit gives operators quick results on targets with reflective surfaces and/or low-scattering surfaces.
The Lus Discovery includes an optical probe linked via optical fibres. What’s more, users can choose any Tecnar probes or designs to meet specific research conditions. When the project advances to the next level, the Lus Discovery can be easily upgraded to the Lus Advance.
The Lus Discovery does not include the laser for non-contact generation of ultrasound or the digitizer to record and store the waveforms. Tecnar’s experts will help you select the best laser and digitizer for your application and use.
CW – Continuous Wave laser
3 W single-frequency power
1064 nm optical wavelength
Frequency stabilized, linewidth < 1MHz
Optical fibre delivery with up to 1 W on target
3 W single frequency power
1064 nm optical wavelength
Frequency stabilized, linewidth < 1MHz
Optical fibre delivery with up to 1 W on target
TWM - Two Wave Mixing photo-refractive receiver
Ultrasonic output bandwidth: 1.0 to 40 MHz
Balanced dual detection for enhanced signal to noise
Input light monitoring detector
Electronic triggering system – TTL outputs
Rack-mount casing
Ultrasonic output bandwidth: 1.0 to 40 MHz
Balanced dual detection for enhanced signal to noise
Input light monitoring detector
Electronic triggering system – TTL outputs
Rack-mount casing
LAB - Laboratory research probe
Optics optimized for 1064 nm wavelength
Three nominal working distances/spot size: 65 mm/0.8 mm, 80 mm/1 mm, 180 mm/2 mm
Industrial grade enclosure IP43
Optics optimized for 1064 nm wavelength
Three nominal working distances/spot size: 2.5 in./0.03 in., 3 in./0.04 in., 7 in./0.08 in.
Industrial grade enclosure IP43
Embark on a seamless research journey with the Lus Explorer, a complete, turnkey laser-ultrasonic system designed for your laboratory studies from the outset.
Tailored for the intricacies of laboratory use, this robust system combines our state-of-the-art Lus Discovery detection unit, a powerful short-pulse laser for noncontact ultrasound generation, and an optical beam delivery system designed for unmatched flexibility of use.
Complemented by a comprehensive data acquisition and processing unit and a flexible two-axis scanning unit, the Lus Explorer ensures immediate operational readiness and superior efficiency.
Built with Tecnar’s renowned expertise and cutting-edge technology, the Lus Explorer empowers you to advance your research capabilities efficiently and effectively.
Start your journey with the Lus Explorer and expand the horizons of your scientific exploration.
CW – Continuous Wave laser
3 W single-frequency power
1064 nm optical wavelength
Frequency stabilized, linewidth < 1MHz
Optical fibre delivery with up to 1 W on target
3 W single frequency power
1064 nm optical wavelength
Frequency stabilized, linewidth < 1MHz
Optical fibre delivery with up to 1 W on target
Short-pulse laser
Nd:YAG Q-switch solid state laser
Optical wavelength 532 nm
Nominal pulse width < 10 nsec
Nominal power output > 50 mJ at 50 Hz
Laser head mounted in HEPg
Nd:YAG Q-switch solid state laser
Optical wavelength 532 nm
Nominal pulse width < 10 nsec
Nominal power output > 50 mJ at 50 Hz
Laser head mounted in HEPg
TWM - Two Wave Mixing photo-refractive receiver
Ultrasonic output bandwidth: 1.0 to 40 MHz
Balanced dual detection for enhanced signal to noise
Input light monitoring detector
Electronic triggering system – TTL outputs
Rack-mount casing
Ultrasonic output bandwidth: 1.0 to 40 MHz
Balanced dual detection for enhanced signal to noise
Input light monitoring detector
Electronic triggering system – TTL outputs
Rack-mount casing
LAB - Laboratory research probe
Optics optimized for 1064 nm wavelength
Three nominal working distances/spot size: 65 mm/0.8 mm, 80 mm/1 mm, 180 mm/2 mm
Industrial grade enclosure IP43
Optics optimized for 1064 nm wavelength
Three nominal working distances/spot size: 2.5 in./0.03 in., 3 in./0.04 in., 7 in./0.08 in.
Industrial grade enclosure IP43
Motorized scanner unit mounted on an optical breadboard
Two axis scanner unit
Full travel span of 100 mm x 100 mm
Compatible with Tecnar’s laser-UT probe
Controlled via integrated software module
Two axis scanner unit
Full travel span of 4 in. x 4 in.
Compatible with Tecnar’s laser-UT probe
Controlled via integrated software module
Move from the lab to the real world. The Lus Advance is a breakthrough technology that makes the industrial use of laser-ultrasonics routine.
Tecnar’s proprietary pulsed detection laser (PDL) is the key to the Lus Advance’s easy, robust, non-contact ultrasonic detection. The target’s surface condition, distance or angle is no longer a limiting factor for laser-ultrasonic applications. Researchers can then extend the use of laser-ultrasonics, while maintaining the flexibility of the Lus Discovery set-up.
The Lus Advance does not include the laser for non-contact generation of ultrasound or the digitizer to record and store the waveforms. Tecnar’s experts will help you select the best laser and digitizer for your application and use.
PDL – Pulsed Detection Laser
Firing rate up to 100 Hz
Peak power > 500 W
Pulse width > 80 µs
Optical wavelength: 1064 nm
Beam delivery via optical fibres
Industrial grade enclosure IP54
Firing rate up to 100 Hz
Peak power > 500 W
Pulse width > 80 µs
Optical wavelength: 1064 nm
Beam delivery via optical fibres
Industrial grade enclosure IP54
TWM - Two Wave Mixing photo-refractive receiver
Ultrasonic output bandwidth: 1.0 to 40 MHz
Balanced dual detection for enhanced signal to noise
Input light monitoring detector
Electronic triggering system – TTL outputs
Rack-mount casing
Ultrasonic output bandwidth: 1.0 to 40 MHz
Balanced dual detection for enhanced signal to noise
Input light monitoring detector
Electronic triggering system – TTL outputs
Rack-mount casing
HEP – Harsh Environment Probe
Using Tecnar Durabeam™ technology
Optics optimized for 1064 nm wavelength
Nominal working distances/spot size: 180 mm/2mm
Industrial grade enclosure IP66
Generation laser enclosure optional
Using Tecnar Durabeam™ technology
Optics optimized for 1064 nm wavelength
Nominal working distances/spot size: 7 in./0.08 in.
Industrial grade enclosure IP66
Generation laser enclosure optional
LAB - Laboratory research probe (optional)
Optics optimized for 1064 nm wavelength
Three nominal working distances/spot size: 65 mm/0.8 mm, 80 mm/1 mm, 180 mm/2 mm
Industrial grade enclosure IP43
Optics optimized for 1064 nm wavelength
Three nominal working distances/spot size: 2.5 in./0.03 in., 3 in./0.04 in., 7 in./0.08 in.
Industrial grade enclosure IP43
With the Lus Ultimate and Tecnar’s know-how and support, you don’t need to be an expert to get the benefits of laser-ultrasonics. This solution is the shortest path from your idea to a mature value-added application.
The Lus Ultimate contains a short pulse laser for non-contact generation of ultrasound, a frequency stabilized high-power pulse laser for non-contact detection of ultrasound (PDL), a fast response laser-ultrasonic receiver based on two waves mixing in a GaAs photorefractive crystal (TWM), a robust optical probe for use in harsh environment (HEPg) assembled with an industrial-grade enclosure with a computer for operation, data storage and data processing. Intensive use of large core optical fibres provides unmatched flexibility in optical probe design, scanning design and target applications.
With its rugged design, the Lus Ultimate can be used everywhere, from laboratory settings to on-site industrial demonstrations.
PDL – Pulsed Detection Laser
Firing rate up to 100 Hz
Peak power > 500 W
Pulse width > 80 µs
Optical wavelength: 1064 nm
Beam delivery via optical fibres
Industrial grade enclosure IP54
Firing rate up to 100 Hz
Peak power > 500 W
Pulse width > 80 µs
Optical wavelength: 1064 nm
Beam delivery via optical fibres
Industrial grade enclosure IP54
Short pulse green laser
Nd:YAG Q-switch solid state laser
Optical wavelength 532 nm
Nominal pulse width < 10 nsec
Nominal power output > 50 mJ at 50 Hz
Laser head mounted in HEPg
Nd:YAG Q-switch solid state laser
Optical wavelength 532 nm
Nominal pulse width < 10 nsec
Nominal power output > 50 mJ at 50 Hz
Laser head mounted in HEPg
TWM - Two Wave Mixing photo-refractive receiver
Ultrasonic output bandwidth: 1.0 to 40 MHz
Balanced dual detection for enhanced signal to noise
Input light monitoring detector
Electronic triggering system – TTL outputs
Rack-mount casing
Ultrasonic output bandwidth: 1.0 to 40 MHz
Balanced dual detection for enhanced signal to noise
Input light monitoring detector
Electronic triggering system – TTL outputs
Rack-mount casing
HEPg – Harsh Environment Probe
Using Tecnar Durabeam™ technology
Optics optimized for 1064 nm wavelength
Nominal working distances/spot size: 180 mm/2mm
Industrial grade enclosure IP66
Generation laser head enclosure included
Using Tecnar Durabeam™ technology
Optics optimized for 1064 nm wavelength
Nominal working distances/spot size: 7 in./0.08 in.
Industrial grade enclosure IP66
Generation laser head enclosure included
Motorized scanner unit
Two axis scanner unit
Full travel span of 100 mm x 100 mm
Compatible with Tecnar’s laser-UT probe
Controlled via integrated software module
Two axis scanner unit
Full travel span of 4 in. x 4 in.
Compatible with Tecnar’s laser-UT probe
Controlled via integrated software module
Integrated data acquisition and control computer
Industrial grade PC with Windows™ operating system
Digitizer with sampling rate of 125 Msamples/sec, 14bits ADC, and 60 MHz bandwidth
Software modules for laser control and data acquisition
Industrial grade PC with Windows™ operating system
Digitizer with sampling rate of 125 Msamples/sec, 14bits ADC, and 60 MHz bandwidth
Software modules for laser control and data acquisition
Leave your details so our experts can contact you. Our team will answer all your questions and suggest the best solution for your needs.